Sirolimus eluting coronary stent
- DES is coated with an immunosuppressant sirolimus that suppresses the proliferation of vascular cells.
Ultra thin strut of cobalt chromium alloy
- As thin as 70 μm, the strut minimizes the burden to blood vessels and facilitates initial endothelialization.
Abluminal bioresorbable polymer
- DES has a medicinal coat only on the area that contacts a blood vessels, which makes it effective in lesion treatment.
- The drugs and polymers coated on the stent are all degradable and thus only the metal compositions will remain.
Improved flexibility
- The open cell structure allows the stent to move flexibly and freely inside complex and curvy blood vessels.
Optimized radial force
- The optimized radial force resists the pressure of a stenosed blood vessel effectively to ensure an adequate space for the stent to pass along it.
Low profile delivery catheter system
- Effective in the treatment of a lesion in a narrow blood vessel.
- It facilitates the stent to move smoothly inside blood vessels.
Hydrophilic coating
- The highly hydrophilic polymer coat on the surface of the catheter offers a good access into curved vessels.
- Drug : Sirolimus
- Drug coating thickness < 4μm
- Stent strut width : < 90μm
- Stent strut thickness : < 70μm
- Nominal Pressure : 9atm(2.25~3.50mm) / 10atm(3.75~4.00mm)
- Rated Burst Pressure : 16atm(2.25~3.50mm) / 14atm(3.75~4.00mm)
Design
-The S-shaped stent strut and bridge help you put the stent into a lesioned cardiovascular vessel easily and ensure a uniform space inside the vessel.
Optimal thickness
- The thickness of the stent strut provides an optimized radial force and facilitates initial endothelialization.
Hydrophilic coating
- The highly hydrophilic polymer coat on the surface of the catheter offers a good access into curved vessels.
Improved flexibility
- The open cell structure allows the stent to move flexibly and freely inside complex and curvy vessels.
Optimized radial force
- The optimized radial force resists the pressure of a stenosed blood vessel effectively to ensure an adequate space for the stent to pass along it.
Low profile delivery catheter system
- Effective in the treatment of a lesion in a narrow blood vessel.
- It prevents damage on blood vessels.
- It facilitates the stent to move smoothly inside blood vessels.
Good visibility in angiography
Made of a cobalt-chromium alloy, the product maintains a high radiopaqueness inside the human body.
Wide choices
Genoss BMS offers a wide range of stent sizes.
Length: 8–28 mm, Diameter: 2–4 mm
Stent strut width : < 90μm
Stent strut thickness : < 70μm
Nominal Pressure : 9atm(2.00~3.50mm) / 10atm(3.75~5.00mm)
Rated Burst Pressure : 16atm(2.00~3.50mm) / 14atm(3.75~5.00mm)